Parts of an Ultrasound Probe丨AKICARE丨Ultrasound Probes
2022-04-28 ·
11:09 AM
Parts of an Ultrasound Probe丨AKICARE丨Ultrasound Probes

Like a golf club, the right ultrasound probe is essential to getting the right picture. The right one is designed to balance depth with frequency. Your ultrasound team should be knowledgeable and helpful in guiding you toward the right probe for your particular needs. The following article covers the various parts of an ultrasound probe: transducer, Doppler shift equation, and Time gain compensation. Read on to learn more. Then, use this information to help you choose the best ultrasound probe for your specific needs.

Ultrasound probes use a transducer to produce ultrasound images. A transducer is an electronic device that translates electrical commands to changing pulses that are applied to piezoelectric crystals. The energy from an ultrasound pulse causes the transducer to heat up, which can harm the patient and decrease its performance. Thermally dispersive structures are designed to reduce this effect. There are two types of ultrasound transducers: linear and helical.
A good all-around device is an ultrasound transducer. This type of device has a large, rounded footprint that provides the patient with a wide sector of imaging. Ultrasound waves fan out from the transducer, which means that there are as many image lines in the far-field as there are close to the transducer. The larger the distance between two image lines, the worse the lateral resolution. For this reason, it is important to check the ultrasound probe’s compatibility.
Another type of transducer is a curved or linear array. These produce ultrasound waves with parallel amplitudes and decrease in wavelength as they travel. These transducers are generally used for imaging certain vessels, like the carotids, as well as for ultrasound-guided procedures. One example of a linear transducer is used in thyroid ultrasound, since the thyroid is situated directly beneath the skin. This type of transducer is also very effective at acquiring a high-quality image, but its resolution is lower than a curved transducer.
Transducers are one of the most important tools of ultrasound equipment. When choosing which transducer to use, it is crucial to think about the type of exams and procedures you plan on performing. We will discuss these in the next part, where we will discuss the standard views of ultrasound images. When selecting a transducer, you should also consider its orientation. You should choose one that is ergonomically designed to provide the maximum control over the transducer.
There are three main types of ultrasound transducers: the curvilinear, the linear array and the phased array. Curvilinear probes are the most widely used for cardiac imaging. The former has a much smaller footprint and a square-shaped lens, which makes it more useful for examining large organs and fast-moving structures. A phased array probe, on the other hand, can be used for abdominal or pelvic exams.
There are different types of transducers. These devices are categorized by size, frequency, and position. One-dimensional array transducers are the most common type, while two-dimensional array transducers are more advanced. They feature piezoelectric elements that move in different directions, such as in the azimuthal direction. The linear array transducer is rectangular in shape. It can also change its beam profile. If a patient is undergoing an ultrasound procedure in the abdomen, this can help the physician determine the extent of the problem.
Parts of an Ultrasound Probe丨AKICARE丨Ultrasound Probes

Time gain compensation丨Ultrasound Probes

A time gain compensation (TGC) setting is an option applied to the ultrasound probe in diagnostic imaging. It reduces the artifacts associated with uneven intensity distribution of B-mode images and normalizes the signal amplitude with time. A TGC module increases the input signal gain as the time sampling is increased. This counteracts the sound-dampening properties of human tissue. This feature is an excellent way to increase resolution in the middle of an image.
Ultrasound imaging systems generally have three different ways to correct for attenuation. An overall gain adjustment will correct for attenuation that occurs throughout the entire field of view, but it may not address attenuation at specific depths. The left and right lobes of the liver, for example, require a different adjustment to amplify the image. The optimum time gain compensation settings are programmable.
Optimal imaging requires precise adjustments to time gain compensation. By adjusting the time gain compensation slope, optimal scanning can be achieved. The overall gain setting will change the internal echo pattern and limit the ability to differentiate cystic and solid lesions. Time gain compensation will also help align the focal zone with the target lesion and better demonstrate retrotumoral characteristics. These features are important when using ultrasound in diagnostics. This article provides an overview of time gain compensation for ultrasound probes.
Generally, an ultrasound probe is set to a mid range position when turned on. However, the optimum position for an ultrasound examination depends on the shape of the structure. A flat probe will create an optimal image when oriented in the middle. Ideally, the ultrasound probe should be able to capture a high-quality image in both curved and smooth structures. The most ideal positioning is a combination of both. This will improve the overall quality of the image.
A transducer is an electrical device that emits and receives ultrasound waves. The ultrasound transducer contains piezoelectric crystals that produce waves when an electrical impulse is applied. Depending on the thickness and propagation rate of the crystals, the resulting signal has a wide bandwidth. This means that even very small echoes are still capable of being interpreted. And if the tissue is too thin or too deep for the probe to penetrate, the signal will not reach the target area.
The ultrasound machine amplifies the signals of deep tissue more than those of superficial tissue. The contrast of the two types of objects can be easily differentiated by observing the difference in brightness and volume of echoes. It can also improve the quality of images by increasing the overall gain and adjusting the echo time to match the target volume. Hence, an ultrasound machine must be adjusted to compensate for refraction effects. For the best imaging results, a transrectal ultrasound machine should remove fecal material.
Parts of an Ultrasound Probe丨AKICARE丨Ultrasound Probes

Doppler shift equation丨Ultrasound Probes

A Doppler shift is a difference in transmitted and received frequencies. It is the result of the motion of red blood cells in a blood column relative to a transducer. The size of the Doppler shift directly correlates to the velocity of the blood column, and its polarity indicates the direction of flow. The Doppler equation for ultrasound probes describes this relationship between the three variables. These are the transmitted frequency, polarity of the reflected signal, and the velocity of the blood flow.
To measure the Doppler shift, use an ultrasound probe with a helical-shaped transducer. In general, the angle of incidence has the greatest impact on the Doppler shift. The lower the angle, the greater the Doppler shift. When the angle is 90 degrees, the shift is minimal. For this reason, it is easy to determine the Doppler shift. A Doppler shift of less than 5 mm is not considered a significant shift.
This equation also applies to moving objects. When a source of sound moves toward an observer, successive wave crests take less time to reach the observer. Because of this, the frequency of the ultrasound is increased. A moving source will have a higher frequency than a stationary observer. A moving object will produce a shock wave or sonic boom. The same applies to ultrasound probes. Doppler shifts for moving objects can help identify strokes or other abnormalities.
The Doppler shift of an ultrasound probe depends on the angle between the source of the sound and the object being studied. To obtain the best Doppler signal, the ultrasound beam should be aligned with the target. A high angle can result in an underestimation of blood velocity. Ideally, the angle should be 0deg. If the angle is too small, however, then the ultrasound probe will miss the target.
Anatomy is a fundamental aspect of ultrasound, and knowledge of regional anatomy will help the user make a more accurate diagnosis. The sciatic nerve is the largest peripheral nerve in the body. However, it is often difficult to identify nerves and arteries close to each other. If you’re unsure which is which, a good rule of thumb is to keep the target in the middle of the field of view.

Sonar is one of the most common applications of ultrasound. Sonar typically uses ultrasonic frequencies in the range of 30.0 to 100 kHz. Some bats and dolphins can even sense distance and velocity with ultrasonic sonar. A Doppler shift equation can help you determine what’s closer. This equation is also useful for identifying the direction of travel of an object. It’s important to note that the depth of reflection of an object is different than that of the medium in which the object is traveling.

Parts of an Ultrasound Probe丨AKICARE丨Ultrasound Probes

Do you have needs? We'd love to help you!

To see our product list and get a special offer

Get Probe List & Best Price

We can repair and make ultrasound probes for most of famous brands like :GE,PHILIPS,SIEMENS,ESAOTE,SAMSUNG,MEDISON,MINDRAY,ALOKA,HITACHI,TOSHIBA,UTRASONIX,SONOSITEFUKUDA,CHISON,SIUI,EDAN,EMPROR,SONOSCAPE,Landwind,etc